Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 10, 2020, 05:39 AM
  • A 0617_A 0616 _01092020_215758.mp4

Date
01/09/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07822
Time
9:39 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7237
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
33
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
A 0617
Downstream MH
A 0616
Dir. of Survey
Downstream
Length Surveyed
748.8 ft.
Total Length
748.8 ft.
Structural Index
3
Structural Quick
Structural Rating
743
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
743
Pipe schematic from manhole A 0617 to A 0616
MH: A 0617MH: A 0616downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06170 ft. MWL - Water Level, 15 %of cross sectional area3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start4.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.9 ft. MGO - General Observation - MAG COAT229.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"675.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"745 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish748.8 ft. AMH - Downstream Manhole, Survey Ends - A 0616748.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
675.6TF
229.1TF
4.9SAV
745SSS
0MWM
3SSS
0AMHA 0617
748.8AMHA 0616
0MWL
4.9MGOMAG COAT
748.8SAV

Properties (6)

additional_info
SC398531
custom_field_two
3
customer
LACSD
datetime
2020-01-09T21:39:29-08:00
documentation
PRO PIPE
is_lateral_inspection
false