Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 3, 2020, 09:23 AM
  • A 0646_A 0645B_01032020_020858.mp4

Date
01/03/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P26640
Time
1:23 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7229
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
A 0646
Downstream MH
A 0645B
Dir. of Survey
Downstream
Length Surveyed
555 ft.
Total Length
555 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole A 0646 to A 0645B
MH: A 0646MH: A 0645Bdownstream0 ft. AMH - Upstream Manhole, Survey Begins - A 06460 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.8 ft. MGO - General Observation - MAG COAT2.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start214 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"555 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish555 ft. MGO - General Observation - U/S MH IN CONSTRUCTION SITE555 ft. MSA - Survey Abandoned - OUT OF CABLE

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
2.8MGOMAG COAT
2.8SAV
0AMHA 0646
214TF
555SAV
0MWM
555MGOU/S MH IN CONSTRUCTION SITE
555MSAOUT OF CABLE
0MWL

Properties (6)

additional_info
SC398521
custom_field_two
5
customer
LACSD
datetime
2020-01-03T01:23:44-08:00
documentation
PRO PIPE
is_lateral_inspection
false