Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 30, 2020, 11:31 AM
  • A 1090_A 0580 _01302020_033802.mp4

Date
01/30/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P22156
Time
3:31 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7247
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Width
72 in.
Upstream MH
A 1090
Downstream MH
A 0580
Dir. of Survey
Downstream
Length Surveyed
11.3 ft.
Total Length
11.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole A 1090 to A 0580
MH: A 1090MH: A 0580downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 10900 ft. MWM - Water Mark, 25 %of cross sectional area7.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES11.3 ft. AMH - Downstream Manhole, Survey Ends - A 0580

Observations (5)

DistanceCodeObservation
11.3AMHA 0580
0MWL
0AMHA 1090
7.5SAV
0MWM

Properties (7)

additional_info
SC398546
custom_field_two
3
customer
LACSD
datetime
2020-01-30T03:31:42-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
34989