Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 23, 2020, 09:24 AM
  • A 1047_A 0594_01232020_014521.mp4

Date
01/23/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07800
Time
1:24 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7245
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
A 1047
Downstream MH
A 0594
Dir. of Survey
Downstream
Length Surveyed
861.5 ft.
Total Length
861.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole A 1047 to A 0594
MH: A 1047MH: A 0594downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 10470 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. MGO - General Observation - MAG COAT THROUGHOUT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start78.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish78.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start450.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"861.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish861.5 ft. AMH - Downstream Manhole, Survey Ends - A 0594

Observations (10)

DistanceCodeObservation
2MGOMAG COAT THROUGHOUT
0AMHA 1047
0MWM
450.2TF
0MWL
861.5SAP
861.5AMHA 0594
78.5SAP
2.1SAV
78.4SAV

Properties (6)

additional_info
SC398543
custom_field_two
3
customer
LACSD
datetime
2020-01-23T01:24:56-08:00
documentation
PRO PIPE
is_lateral_inspection
false