Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 15, 2020, 05:06 PM
  • 29 0689_29 0264 _01152020_092852.mp4

Date
01/15/2020
W/O
808558
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00550
PipeID
P24169
Time
9:06 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6848
Sewer Name
29 WEST HILL STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_808558_TV29063_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0689
Downstream MH
29 0264
Dir. of Survey
Downstream
Length Surveyed
347.8 ft.
Total Length
347.8 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 29 0689 to 29 0264
MH: 29 0689MH: 29 0264downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 06890 ft. MWL - Water Level, 5 %of cross sectional area30.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"75.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"188.3 ft. FS - Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES193.6 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES194.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"197.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"254.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"296.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"329.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"347.8 ft. AMH - Downstream Manhole, Survey Ends - 29 0264

Observation photos (2)

  • Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES

    188.3 ft. - Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    193.6 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWM
347.8AMH29 0264
0AMH29 0689
188.3FS
0MWL
75.8TFA
329.9TF
197.4TFC
254.6TFC
296.7TFC
30.7TFC
194.7TF
193.6FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2020-01-15T09:06:15-08:00
documentation
PRO PIPE
is_lateral_inspection
false