A 0533_A 0532_2272020_043924.mp4
1 ft. - Water Mark, 50 %of cross sectional area - OLD WATER MARK
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
2 ft. - General Observation - 75% MAG COAT START
2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
16 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
17.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
112.1 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
336.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
417.5 ft. - General Observation - 90% MAG COAT
561.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
| Distance | Code | Observation |
|---|---|---|
| 667.2 | SSS | BLISTERING PEELING CONCRETE |
| 16 | SAV | SEVERE AGG |
| 417.5 | MGO | 90% MAG COAT |
| 336.3 | SAV | SEVERE AGG |
| 667.9 | AMH | 5:05AM |
| 667.2 | SAV | SEVERE AGG SPORATIC |
| 667.2 | DAGS | — |
| 17.5 | SSS | PEELING CONCRETE |
| 667.2 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 0 | MWL | — |
| 0 | MWM | — |
| 112.1 | SAV | SEVERE AGG SPORATIC |
| 2 | DAGS | — |
| 2 | MGO | 75% MAG COAT START |
| 2 | SAV | SEVERE AGG |
| 1 | MWM | OLD WATER MARK |
| 0 | AMH | 4:25AM |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 561.9 | SSS | PEELING CONCRETE |