Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2020, 10:38 AM
  • 15 0760_15 0759A_2262020_025237.mp4

Date
02/26/2020
W/O
0813511
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P25010
Time
2:38 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1369
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20200226MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0760
Downstream MH
15 0759A
Dir. of Survey
Downstream
Length Surveyed
173.6 ft.
Total Length
173.6 ft.
Structural Index
3
Structural Quick
4222
Structural Rating
12
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 15 0760 to 15 0759A
MH: 15 0760MH: 15 0759Adownstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:50AM2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE SEVERE AGG ATTACHED9.4 ft. RFJ - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YESR - 3%17.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open19.5 ft. MGO - General Observation - MAG COAT 10% START19.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped25.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED73.8 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG77.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open114.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open129.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open171.6 ft. MGO - General Observation - FLOW MONTERING BAND AROUND PIPE173.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - PEELING FLAKING CONCRETE SEVERE AGG ATTACHED173.1 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG173.1 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active173.1 ft. MGO - General Observation - 10% MAG COAT FINISH173.6 ft. AMH - Downstream Manhole, Survey Ends - 3:10AM

Observation photos (6)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE SEVERE AGG ATTACHED

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE SEVERE AGG ATTACHED

  • General Observation - MAG COAT 10% START

    19.5 ft. - General Observation - MAG COAT 10% START

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED

    25.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    73.8 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • General Observation - FLOW MONTERING BAND AROUND PIPE

    171.6 ft. - General Observation - FLOW MONTERING BAND AROUND PIPE

Observations (20)

DistanceCodeObservation
19.5MGOMAG COAT 10% START
9.4RFJ3%
173.1SSSPEELING FLAKING CONCRETE SEVERE AGG ATTACHED
0MWM
129.3TFOpen
2SAMSEVERE AGG
173.1SAMSEVERE AGG
173.6AMH3:10AM
114.4TFOpen
77.5TFOpen
17.4TFOpen
2SSSPEELING FLAKING CONCRETE SEVERE AGG ATTACHED
19.5TFCCapped
25.4SSSPEELING CONCRETE SEVERE AGG ATTACHED
173.1MGOConn. @ Mh, 9 O' Clock. Active
0MWL
171.6MGOFLOW MONTERING BAND AROUND PIPE
173.1MGO10% MAG COAT FINISH
73.8SAMSEVERE AGG
0AMH2:50AM

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED
custom_field_two
2
customer
LACSD
datetime
2020-02-26T02:38:47-08:00
documentation
MARTIN,REVELES,CASTILLO
is_lateral_inspection
false