Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 5, 2020, 10:56 AM
  • 01 0723_01 0722_02052020_030854.mp4

Date
02/05/2020
W/O
808072
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00195
PipeID
P01433
Time
2:56 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7304
Sewer Name
01 BULLIS ROAD RELIEF TRUNK, SECTION 1
City
LYNWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_808072_TV01259_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0723
Downstream MH
01 0722
Dir. of Survey
Downstream
Length Surveyed
328.8 ft.
Total Length
328.8 ft.
Structural Index
3
Structural Quick
3B27
Structural Rating
62
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
192
Pipe schematic from manhole 01 0723 to 01 0722
MH: 01 0723MH: 01 0722downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 07232 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start7.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start83.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish166.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start201.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish215.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES327.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish328.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE328.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0722

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    7.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    166.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    215.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    328.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (12)

DistanceCodeObservation
328.8MGOCOCKROACHES IN MANHOLE
166.2CL
7.9FL
83.4FL
0MWL
2DAGS
201.6CL
327.9DAGS
215.7CM
0MWM
328.8AMH01 0722
0AMH01 0723

Properties (6)

additional_info
SC398789
custom_field_two
2
customer
LACSD
datetime
2020-02-05T02:56:16-08:00
documentation
PRO PIPE
is_lateral_inspection
false