Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 10, 2020, 10:12 AM
  • 02 0900_02 0899_02102020_022122.mp4

Date
02/10/2020
W/O
808148
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00252
PipeID
P03468
Time
2:12 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7253
Sewer Name
02 DOWNEY-BELLFLOWER DIVERSION TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_808148_TV02380_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
02 0900
Downstream MH
02 0899
Dir. of Survey
Downstream
Length Surveyed
352.9 ft.
Total Length
352.9 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
207
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
207
Pipe schematic from manhole 02 0900 to 02 0899
MH: 02 0900MH: 02 0899downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 09000 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area7.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start352 ft. MGO - General Observation - Surface Spalling, from 9 to 3 oclock, throughout the reach352 ft. MGO - General Observation - Grease Deposits, from 4 to 8 oclock, 5%, throughout the reach352.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352.9 ft. AMH - Downstream Manhole, Survey Ends - 02 0899

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH02 0900
0MWM
352MGOSurface Spalling, from 9 to 3 oclock, throughout the reach
7.3CM
352.9CM
352MGOGrease Deposits, from 4 to 8 oclock, 5%, throughout the reach
0MWL
352.9AMH02 0899

Properties (6)

additional_info
SC398853
custom_field_two
3
customer
LACSD
datetime
2020-02-10T02:12:30-08:00
documentation
PROPIPE
is_lateral_inspection
false