Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2020, 05:47 AM
  • 02 0907_02 0906_02052020_215802.mp4

Date
02/05/2020
W/O
808148
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00252
PipeID
P03475
Time
9:47 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7252
Sewer Name
02 DOWNEY-BELLFLOWER DIVERSION TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_808148_TV02380_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
02 0907
Downstream MH
02 0906
Dir. of Survey
Downstream
Length Surveyed
293.5 ft.
Total Length
293.5 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
171
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
171
Pipe schematic from manhole 02 0907 to 02 0906
MH: 02 0907MH: 02 0906downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 09070 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 45 %of cross sectional area6.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start293 ft. MGO - General Observation - Slight grease throughout the reach, 4 to 8 oclock, 5%293.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish293.5 ft. AMH - Downstream Manhole, Survey Ends - 02 0906

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMH02 0907
293MGOSlight grease throughout the reach, 4 to 8 oclock, 5%
293.3CM
0MWL
293.5AMH02 0906
0MWM
6.3CM

Properties (6)

additional_info
SC398852
custom_field_two
3
customer
LACSD
datetime
2020-02-05T21:47:29-08:00
documentation
PROPIPE
is_lateral_inspection
false