Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2020, 08:35 AM
  • 32 1069_32 1068_02132020_005318.mp4

Date
02/13/2020
W/O
808150
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19517
Time
12:35 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7406
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_808150_TV32058_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1069
Downstream MH
32 1068
Dir. of Survey
Downstream
Length Surveyed
370.2 ft.
Total Length
370.2 ft.
Structural Index
3
Structural Quick
3322
Structural Rating
13
O&M Index
2
O&M Quick
2N00
O&M Rating
146
Overall Index
2
Overall Quick
Overall Rating
159
Pipe schematic from manhole 32 1069 to 32 1068
MH: 32 1069MH: 32 1068downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 10690 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start21 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"26.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"35.2 ft. MGO - General Observation - ABANDONED MH43 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"44 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"46.3 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES99.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"181.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.9 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES191.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES197.4 ft. FS - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES210 ft. CS - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES229.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"234 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"323.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"328.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"367.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish370.2 ft. AMH - Downstream Manhole, Survey Ends - 32 1068

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    46.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    184.9 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    191.7 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    197.4 ft. - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    210 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
46.3CL
99.4TFC
191.7FL
0AMH32 1069
367.5DAGS
43TBA
0MWM
35.2MGOABANDONED MH
197.4FS
21TFC
184.9FS
328.8TFC
181.6TFC
44TBA
229.4TFA
234TFA
210CS
2DAGS
177.2TFC
105.3TFC
370.2AMH32 1068
0MWL
323.2TFC
26.6TFC

Properties (6)

additional_info
SC398795
custom_field_two
2
customer
LACSD
datetime
2020-02-13T00:35:47-08:00
documentation
PRO PIPE
is_lateral_inspection