Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2020, 08:53 AM
  • 32 1068_32 1067_02132020_010606.mp4

Date
02/13/2020
W/O
808150
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19516
Time
12:53 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7406
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_808150_TV32058_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1068
Downstream MH
32 1067
Dir. of Survey
Downstream
Length Surveyed
295 ft.
Total Length
295 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2K00
O&M Rating
116
Overall Index
2
Overall Quick
Overall Rating
120
Pipe schematic from manhole 32 1068 to 32 1067
MH: 32 1068MH: 32 1067downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 10680 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start24.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"29.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"72.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"101.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"107.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"153.1 ft. CS - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES177.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"182.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"222.5 ft. CS - Crack Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES254.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"259.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"292.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish295 ft. MGO - General Observation - COCKROACHES IN MANHOLE295 ft. AMH - Downstream Manhole, Survey Ends - 32 1067295 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

    153.1 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES

    222.5 ft. - Crack Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    295 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (19)

DistanceCodeObservation
295MGOCOCKROACHES IN MANHOLE
0MWL
0AMH32 1068
24.8TFC
222.5CS
29.3TFC
0MWM
107.3TFC
254.7TFA
2DAGS
72.5TBA
259.8TFC
153.1CS
295AMH32 1067
101.3TFA
292.7DAGS
295MGOCONNECTION AT MH 9 O'CLOCK
182.9TFC
177.2TFA

Properties (6)

additional_info
SC398795
custom_field_two
3
customer
LACSD
datetime
2020-02-13T00:53:32-08:00
documentation
PRO PIPE
is_lateral_inspection
false