Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2020, 09:31 AM
  • 32 1065_32 1064_02132020_014447.mp4

Date
02/13/2020
W/O
808150
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19513
Time
1:31 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7406
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_808150_TV32058_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1065
Downstream MH
32 1064
Dir. of Survey
Downstream
Length Surveyed
293.3 ft.
Total Length
293.3 ft.
Structural Index
4
Structural Quick
4F33
Structural Rating
151
O&M Index
2
O&M Quick
2K00
O&M Rating
116
Overall Index
3
Overall Quick
Overall Rating
267
Pipe schematic from manhole 32 1065 to 32 1064
MH: 32 1065MH: 32 1064downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 10652 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.3 ft. CS - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES24.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"29.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"39 ft. FS - Fracture Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES63 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES80.9 ft. FS - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES86.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start94.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"99.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"171.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"247.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"251.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"262.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish290.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish293.3 ft. AMH - Downstream Manhole, Survey Ends - 32 1064293.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK293.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

    4.3 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

    39 ft. - Fracture Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    80.9 ft. - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    86.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    293.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (23)

DistanceCodeObservation
251.7TFC
171.4TFC
2DAGS
0MWL
29.1TFC
86.8FM
293.3AMH32 1064
247.3TFC
290.6DAGS
39FS
293.3MGOCONNECTION AT MH 9 O'CLOCK
176.1TFC
262.1FM
94.1TFC
63CM
0MGOCONNECTION AT MH 3 O'CLOCK
293.3MGOCOCKROACHES IN MANHOLE
80.9FS
99.7TFC
0MWM
4.3CS
0AMH32 1065
24.4TFC

Properties (6)

additional_info
SC398795
custom_field_two
2
customer
LACSD
datetime
2020-02-13T01:31:32-08:00
documentation
PRO PIPE
is_lateral_inspection
false