Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 7, 2020, 06:03 AM
  • A 0607_ A 0606 __06022020_221534.mp4

Date
02/06/2020
W/O
803059
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00316
PipeID
P07812
Time
10:03 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
k7309
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_803059_TV21041_DEC2019
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Width
51 in.
Upstream MH
A 0606
Downstream MH
A 0607
Dir. of Survey
Upstream
Length Surveyed
4 ft.
Total Length
4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole A 0606 to A 0607
MH: A 0606MH: A 0607upstream0 ft. MGO - General Observation - UP LEG OF THE D/S SIPHON0 ft. MSA - Survey Abandoned - DUE TO SIPHON2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES4 ft. AMH - Downstream Manhole, Survey Begins - A 06064 ft. MWM - Water Mark, 100 %of cross sectional area4 ft. MWL - Water Level, 90 %of cross sectional area

Observations (6)

DistanceCodeObservation
4MGOUP LEG OF THE D/S SIPHON
2SAV
0AMHA 0606
0MWM
0MWL
4MSADUE TO SIPHON

Properties (6)

additional_info
SC378790
custom_field_two
3
customer
LACSD
datetime
2020-02-06T22:03:38-08:00
documentation
PRO PIPE
is_lateral_inspection
false