Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2016, 11:46 AM
  • 01 1199_01 1199A_09142016_Manual.mp4

Date
09/14/2016
W/O
0585843
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00226
PipeID
P02110
Time
4:46 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0276
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
SOUTH GATE
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Routine Assessment
Project
20190914VMR_WILCOX_AVENUE_TRUNK_EXTENSION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Upstream MH
01 1199
Downstream MH
01 1199A
Dir. of Survey
Upstream
Length Surveyed
80.6 ft.
Total Length
80.6 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 01 1199 to 01 1199A
MH: 01 1199MH: 01 1199Aupstream0 ft. MSA - Survey Abandoned - MH MISSING4.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES9.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4"16 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish70.5 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES77.6 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES80.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start80.6 ft. MWM - Water Mark, 50 %of cross sectional area80.6 ft. AMH - Downstream Manhole, Survey Begins - 04:48 AM80.6 ft. MWL - Water Level, 30 %of cross sectional area

Observations (10)

DistanceCodeObservation
0CL
80.6MSAMH MISSING
76.5CL
0MWM
0AMH04:48 AM
10.1CM
0MWL
3CM
64.6CL
71.5TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2016-09-14T04:46:47-07:00
documentation
REVELES, MANANES, OLIVER III
is_lateral_inspection
false