Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2016, 09:29 AM
  • 19 0247_19 0246_09132016_Manual.mp4

Date
09/13/2016
W/O
0585465
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00728
PipeID
P15217
Time
2:29 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0274
Sewer Name
19 STUDEBAKER ROAD TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
20190913VMR_STUDEBAKER_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
19 0247
Downstream MH
19 0246
Dir. of Survey
Downstream
Length Surveyed
260.5 ft.
Total Length
260.5 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 19 0247 to 19 0246
MH: 19 0247MH: 19 0246downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 03:10 AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"32.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open122.3 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 10% Roots125.8 ft. CC - Crack Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES139.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"235.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"253.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"260.5 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 5"260.5 ft. AMH - Downstream Manhole, Survey Ends - 03:54 AM

Observation photos (1)

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 10% Roots

    122.3 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 10% Roots

Observations (12)

DistanceCodeObservation
0MWL
0AMH03:10 AM
32.1TFOpen
253.1TF
139.6TF
0MWM
260.5TFA
125.8CC
0TFA
235.4TF
260.5AMH03:54 AM
122.3TFD10% Roots

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2016-09-13T02:29:00-07:00
documentation
REVELES, MANANES, OLIVER III
is_lateral_inspection
false