- Date
- 09/26/2016
- W/O
- 0585465
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00728
- PipeID
- P15210
- Time
- 1:52 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7241
- Sewer Name
- 19 STUDEBAKER ROAD TRUNK
- City
- CERRITOS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- 20160926MDM_STUDEBAKER_ROAD_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 19 0239
- Downstream MH
- 19 0240
- Dir. of Survey
- Upstream
- Length Surveyed
- 350.2 ft.
- Total Length
- 350.2 ft.
- Structural Index
- 2
- Structural Quick
- 2200
- Structural Rating
- 4
- O&M Index
- 3
- O&M Quick
- 3200
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 19 0239 to 19 0240 Observation photos (4)

8 ft. - General Observation - 15" VCP

161.1 ft. - Water Level, 5 %of cross sectional area

317.7 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 12 to 03 o'clock, , within 8 inches of joint: YES

317.7 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 6" - OPEN 100% BLOCKED GREASE