Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2016, 08:27 PM
  • 02 0714B_02 0714A_9142016_134213.mp4

Date
09/14/2016
W/O
0591680
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00294
PipeID
P18784
Time
1:27 PM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7233
Sewer Name
02 OLD RIVER SCHOOL RD. TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
29
Purpose
Capital Improvement Program Assesment
Project
20160914AM_OLD_RIVER_SCHOOL_ROAD_TRUNK_SECTS_1_2
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0714A
Downstream MH
02 0714B
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 02 0714A to 02 0714B
MH: 02 0714AMH: 02 0714Bupstream0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON0.1 ft. LU - Alignment Up, 45 %0.1 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO0.1 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO2.1 ft. MGO - General Observation - ROACHES INSIDE THE MH.2.1 ft. AMH - Downstream Manhole, Survey Begins - 1:42 PM2.1 ft. MGO - General Observation - SQUARE CUT OUT WITH SOIL VISIBLE2.1 ft. MWL - Water Level, 100 %of cross sectional area

Observation photos (7)

  • Downstream Manhole, Survey Begins - 1:42 PM

    0 ft. - Downstream Manhole, Survey Begins - 1:42 PM

  • General Observation - SQUARE CUT OUT WITH SOIL VISIBLE

    0 ft. - General Observation - SQUARE CUT OUT WITH SOIL VISIBLE

  • Water Level, 100 %of cross sectional area

    0 ft. - Water Level, 100 %of cross sectional area

  • Alignment Up, 45 %

    2 ft. - Alignment Up, 45 %

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

    2.1 ft. - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

Observations (8)

DistanceCodeObservation
0MGOROACHES INSIDE THE MH.
2.1MSAVIEW OF THE UPLEG PIPE OF THE D/S SIPHON
0AMH1:42 PM
2LU
0MGOSQUARE CUT OUT WITH SOIL VISIBLE
0MWL
2SSS
2SAV

Properties (6)

additional_info
RFIR INSPECTION, VIEW OF THE UPLEG PIPE OF THE D/S SIPHON, SOUTH BARREL
custom_field_two
3
customer
LACSD
datetime
2016-09-14T13:27:27-07:00
documentation
MIRANDA, SHADLER, FRANKLIN, BRAR
is_lateral_inspection
false