Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 7, 2016, 12:35 PM
  • 05 1961_05 1960_972016_053757.mp4

Date
09/07/2016
W/O
0585481
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00503
PipeID
P07487
Time
5:35 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0268
Sewer Name
05 PALOS VERDES NORTH SLOPE TRUNK, SECTS 2&3
City
PALOS VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
34
Purpose
Routine Assessment
Project
20160906MDM_PALOS_VERDES_NORTH_SLOPE_TRUNK_SECTS_2_3
Material
Vitrified Clay Pipe
Shape
Circular
Height
14 in.
Upstream MH
05 1961
Downstream MH
05 1960
Dir. of Survey
Downstream
Length Surveyed
363.9 ft.
Total Length
363.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 1961 to 05 1960
MH: 05 1961MH: 05 1960downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:35AM0 ft. MWM - Water Mark, 30 %of cross sectional area33.7 ft. MGO - General Observation - 14" VCP CIPP112 ft. TBD - Tap Break-In Defective, at 11 o'clock, -, , within 8 inches of joint: NO, 6" - ACTIVE -80% ROOTS304.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active363.9 ft. AMH - Downstream Manhole, Survey Ends - 5:55AM

Observation photos (1)

  • General Observation - 14" VCP CIPP

    33.7 ft. - General Observation - 14" VCP CIPP

Observations (7)

DistanceCodeObservation
304.4TBActive
0MWL
0AMH5:35AM
0MWM
33.7MGO14" VCP CIPP
363.9AMH5:55AM
112TBDACTIVE -80% ROOTS

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2016-09-07T05:35:14-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false