Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 2, 2016, 07:39 AM
Date
09/02/2016
W/O
0591702
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00013
PipeID
P00371
Time
12:39 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0265
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
20160902VMR_KEYSTONE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0323
Downstream MH
08 0322
Dir. of Survey
Downstream
Length Surveyed
250.6 ft.
Total Length
250.6 ft.
Structural Index
2
Structural Quick
2714
Structural Rating
18
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
18
Pipe schematic from manhole 08 0323 to 08 0322
MH: 08 0323MH: 08 0322downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03:30 AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0.2 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 8"4.7 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES4.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES4.7 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES9.3 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start9.3 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start14.8 ft. CC - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES38.8 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES53.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"73.7 ft. MGP - General Photograph149.2 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES222.7 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish222.7 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish239.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES243.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES243.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES250.3 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 10"250.3 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 10"250.6 ft. AMH - Downstream Manhole, Survey Ends - 03:54 AM

Observation photos (1)

  • General Photograph

    73.7 ft. - General Photograph

Observations (22)

DistanceCodeObservation
53.6TFC
243.3CL
9.3CL
149.2CC
14.8CC
250.3TFA
0AMH03:30 AM
4.7CC
222.7CL
73.7MGP
4.7CL
239.1CL
243.3CL
9.3CL
250.3TFA
4.7CL
38.8CC
0MWM
0.2TFA
0MWL
222.7CL
250.6AMH03:54 AM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2016-09-02T00:39:02-07:00
documentation
REVELES, MANANES, OLVER III
is_lateral_inspection
false