Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2020, 09:27 AM
  • 08 0006_08 0005_2132020_021118.mp4

Date
02/13/2020
W/O
0808146
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00006
Time
1:27 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1356
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Capital Improvement Program Assesment
Project
20200213MDM_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0006
Downstream MH
08 0005
Dir. of Survey
Downstream
Length Surveyed
259.9 ft.
Total Length
259.9 ft.
Structural Index
5
Structural Quick
5841
Structural Rating
44
O&M Index
3
O&M Quick
3300
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
53
Pipe schematic from manhole 08 0006 to 08 0005
MH: 08 0006MH: 08 0005downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM2 ft. MGO - General Observation - 100% MISSING TILES START2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR4.4 ft. SMW - Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID4.4 ft. SMW - Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID4.4 ft. SMW - Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID9.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR MISSING14.3 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - TILES UNDER FLOW21.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR CORRISON BEYOND REBAR60.1 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - MISSING TILES UNDER FLOW104.9 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - MISSING TILES UNDER FLOW109.7 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR124.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR259 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR MISSING CORRISON BEYOUND REBAR259 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG259 ft. MGO - General Observation - 100% MISSING TILES FINISH259.9 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observation photos (11)

  • General Observation - 100% MISSING TILES START

    2 ft. - General Observation - 100% MISSING TILES START

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID

    4.4 ft. - Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID

  • Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID

    4.4 ft. - Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID

  • Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID

    4.4 ft. - Surface Missing Wall, from 10 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE SLIGHT VOID

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR MISSING

    9.3 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR MISSING

  • Deposits Settled Other,  20 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO - TILES UNDER FLOW

    14.3 ft. - Deposits Settled Other, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - TILES UNDER FLOW

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR CORRISON BEYOND REBAR

    21.2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR CORRISON BEYOND REBAR

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    109.7 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    124.3 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

Observations (21)

DistanceCodeObservation
9.3SRCLONG CIRCUM REBAR MISSING
2MGO100% MISSING TILES START
2SAMSEVERE AGG
259.9AMH1:30AM
259SRCLONG CIRCUM REBAR MISSING CORRISON BEYOUND REBAR
14.3DSZTILES UNDER FLOW
21.2SRCMISSING REBAR CORRISON BEYOND REBAR
4.4SMWSOIL VISIBLE SLIGHT VOID
0MGOConn. @ Mh, 3 O' Clock. Active
0MWM
2SRCLONG CIRCUM REBAR
109.7SRCLONG CIRCUM REBAR
124.3SRCBROKEN MISSING REBAR
259SAMSEVERE AGG
4.4SMWSOIL VISIBLE SLIGHT VOID
259MGO100% MISSING TILES FINISH
0MWL
4.4SMWSOIL VISIBLE SLIGHT VOID
60.1DSZMISSING TILES UNDER FLOW
104.9DSZMISSING TILES UNDER FLOW
0AMH1:55AM

Properties (4)

customer
LACSD
datetime
2020-02-13T01:27:23-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false