Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2016, 12:40 PM
  • 15 0372_15 0371A_642016_060220.mp4

Date
06/04/2016
W/O
0563341
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00598
PipeID
P20533
Time
5:40 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0150
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
18
Purpose
Routine Assessment
Project
20160604MDM_BALDWIN_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
15 0372
Downstream MH
15 0371A
Dir. of Survey
Downstream
Length Surveyed
309.7 ft.
Total Length
309.7 ft.
Structural Index
3
Structural Quick
3400
Structural Rating
12
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 15 0372 to 15 0371A
MH: 15 0372MH: 15 0371Adownstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 5:50AM1 ft. MMC - Material Change, Concrete pipe (non-reinfored) - PIPE IS NOT VCP2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG44.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG185.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG188.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG290.2 ft. MWL - Water Level, 30 %of cross sectional area290.2 ft. MWM - Water Mark, 50 %of cross sectional area309.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active309.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG309.7 ft. AMH - Downstream Manhole, Survey Ends - 6:15AM

Observation photos (5)

  • Material Change, Concrete pipe (non-reinfored) - PIPE IS NOT VCP

    1 ft. - Material Change, Concrete pipe (non-reinfored) - PIPE IS NOT VCP

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    44.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    185.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    188.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

Observations (14)

DistanceCodeObservation
0MWM
290.2MWL
1MMCPIPE IS NOT VCP
290.2MWM
309.3MGOConn. @ Mh, 3 O' Clock. Active
0MWL
0MGOConn. @ Mh, 3 O' Clock. Active
2SAVSEVERE AGG
44.6SAVSEVERE AGG
185.3SAVSEVERE AGG
309.3SAVSEVERE AGG
188.5SAVSEVERE AGG
309.7AMH6:15AM
0AMH5:50AM

Properties (6)

custom_field_three
SEVERE AGG VISIBLE
custom_field_two
3
customer
LACSD
datetime
2016-06-04T05:40:51-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false