Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 14, 2020, 08:50 AM
  • 02 1569A_02 1569_2142020_020434.mp4

Date
02/14/2020
W/O
0813917
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00231
PipeID
P04020
Time
12:50 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1351
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 2
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
20200214MDM_ARIZONZ_AVENUE_TRUNK_SECTION_2
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
02 1569A
Downstream MH
02 1569
Dir. of Survey
Downstream
Length Surveyed
301.9 ft.
Total Length
301.9 ft.
Structural Index
3
Structural Quick
3700
Structural Rating
21
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
27
Pipe schematic from manhole 02 1569A to 02 1569
MH: 02 1569AMH: 02 1569downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 12 O' Clock. OPEN STOPLOG IN PLACE UPSTREAM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM1 ft. MGO - General Observation - PIPE OPENING SMALLER THAN NORMAL8 ft. MGO - General Observation - 10" NRCP-PVCP SPIRAL LINER13.2 ft. RFB - Roots Fine Barrell, from 03 to 06 o'clock, within 8 inches of joint: NO - 2%14.7 ft. RFB - Roots Fine Barrell, from 10 to 02 o'clock, within 8 inches of joint: NO - 1% POSSIBLE LINER MATERIAL45.1 ft. RFB - Roots Fine Barrell, from 05 to 06 o'clock, within 8 inches of joint: NO - 1% POSSIBLE LINER MATERIAL102 ft. LFD - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL102 ft. LFD - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRALS PIPE VISIBLE102 ft. LFD - Lining Failure Detached, from 01 to 05 o'clock, within 8 inches of joint: NO - LOOSE SPIRAL102 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6" - Active213.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open225 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Open300.5 ft. LFD - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL301.6 ft. LFD - Lining Failure Detached, from 11 to 05 o'clock, within 8 inches of joint: NO - MISSING SPIRAL END OF PIPE301.6 ft. MGO - General Observation - Conn. @ Mh, 12 O' Clock. Active301.6 ft. LFD - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - LOOSE SPIRAL END OF PIPE301.6 ft. LFD - Lining Failure Detached, from 10 to 02 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL301.6 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active301.9 ft. AMH - Downstream Manhole, Survey Ends - 2:45AM

Observation photos (12)

  • General Observation - PIPE OPENING SMALLER THAN NORMAL

    1 ft. - General Observation - PIPE OPENING SMALLER THAN NORMAL

  • General Observation - 10" NRCP-PVCP SPIRAL LINER

    8 ft. - General Observation - 10" NRCP-PVCP SPIRAL LINER

  • Roots Fine Barrell, from 03 to 06 o'clock, within 8 inches of joint: NO - 2%

    13.2 ft. - Roots Fine Barrell, from 03 to 06 o'clock, within 8 inches of joint: NO - 2%

  • Roots Fine Barrell, from 10 to 02 o'clock, within 8 inches of joint: NO - 1% POSSIBLE LINER MATERIAL

    14.7 ft. - Roots Fine Barrell, from 10 to 02 o'clock, within 8 inches of joint: NO - 1% POSSIBLE LINER MATERIAL

  • Roots Fine Barrell, from 05 to 06 o'clock, within 8 inches of joint: NO - 1% POSSIBLE LINER MATERIAL

    45.1 ft. - Roots Fine Barrell, from 05 to 06 o'clock, within 8 inches of joint: NO - 1% POSSIBLE LINER MATERIAL

  • Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL

    102 ft. - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL

  • Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRALS PIPE VISIBLE

    102 ft. - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRALS PIPE VISIBLE

  • Lining Failure Detached, from 01 to 05 o'clock, within 8 inches of joint: NO - LOOSE SPIRAL

    102 ft. - Lining Failure Detached, from 01 to 05 o'clock, within 8 inches of joint: NO - LOOSE SPIRAL

  • Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL

    300.5 ft. - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL

  • Lining Failure Detached, from 11 to 05 o'clock, within 8 inches of joint: NO - MISSING SPIRAL END OF PIPE

    301.6 ft. - Lining Failure Detached, from 11 to 05 o'clock, within 8 inches of joint: NO - MISSING SPIRAL END OF PIPE

  • Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - LOOSE SPIRAL END OF PIPE

    301.6 ft. - Lining Failure Detached, from 07 to 11 o'clock, within 8 inches of joint: NO - LOOSE SPIRAL END OF PIPE

  • Lining Failure Detached, from 10 to 02 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL

    301.6 ft. - Lining Failure Detached, from 10 to 02 o'clock, within 8 inches of joint: NO - SEPERATED SPIRAL

Observations (22)

DistanceCodeObservation
102LFDSEPERATED SPIRAL
1MGOPIPE OPENING SMALLER THAN NORMAL
301.6LFDMISSING SPIRAL END OF PIPE
301.6MGOConn. @ Mh, 12 O' Clock. Active
213.4TBOpen
0MWL
301.6LFDLOOSE SPIRAL END OF PIPE
102LFDSEPERATED SPIRALS PIPE VISIBLE
8MGO10" NRCP-PVCP SPIRAL LINER
0MGOConn. @ Mh, 12 O' Clock. OPEN STOPLOG IN PLACE UPSTREAM
13.2RFB2%
301.6LFDSEPERATED SPIRAL
0MWM
102LFDLOOSE SPIRAL
301.9AMH2:45AM
45.1RFB1% POSSIBLE LINER MATERIAL
300.5LFDSEPERATED SPIRAL
0AMH1:55AM
14.7RFB1% POSSIBLE LINER MATERIAL
301.6MGOConn. @ Mh, 3 O' Clock. Active
225TBOpen
102TBActive

Properties (7)

custom_field_three
SEPERATED SPIRALS PIPE VISIBLE
custom_field_two
2
customer
LACSD
datetime
2020-02-14T00:50:36-08:00
documentation
MARTIN,REVELES,CASTILLO
is_lateral_inspection
false
lining
PVCP