Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2020, 10:58 AM
  • 02 1577_02 1576A_262020_031601.mp4

Date
02/06/2020
W/O
0813917
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00231
PipeID
P04028
Time
2:58 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1349
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 2
City
LOS ANGLES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
20200206MDM_ARIZONA_AVENUE_TRUNK_SECTION_2
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
02 1577
Downstream MH
02 1576A
Dir. of Survey
Downstream
Length Surveyed
80.8 ft.
Total Length
80.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 1577 to 02 1576A
MH: 02 1577MH: 02 1576Adownstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. ACTIVE0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:15AM29.6 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - Open74.4 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6" - Open75.6 ft. MGO - General Observation - 10" NRCP-PEP80.8 ft. AMH - Downstream Manhole, Survey Ends(ABANDONED MH) - 3:25AM(ABANDONED MH)

Observation photos (2)

  • General Observation - 10" NRCP-PEP

    75.6 ft. - General Observation - 10" NRCP-PEP

  • Downstream Manhole, Survey Ends(ABANDONED MH) - 3:25AM(ABANDONED MH)

    80.8 ft. - Downstream Manhole, Survey Ends(ABANDONED MH) - 3:25AM(ABANDONED MH)

Observations (8)

DistanceCodeObservation
0MWM
0MGOConn. @ Mh, 3 O' Clock. ACTIVE
75.6MGO10" NRCP-PEP
0MWL
0AMH3:15AM
74.4TBOpen
80.8AMH3:25AM(ABANDONED MH)
29.6TBOpen

Properties (7)

custom_field_three
LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2020-02-06T02:58:14-08:00
documentation
MARTIN,CASTILLO
is_lateral_inspection
false
lining
PEP