Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 17, 2020, 06:47 AM
  • 18 1193_18 1192 _01162020_225923.mp4

Date
01/16/2020
W/O
808210
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00687
PipeID
P15038
Time
10:47 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7276
Sewer Name
18 LOWER SPRINGS ROAD TRUNK REPLACEMENT
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_808210_TV18109_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 1192
Downstream MH
18 1193
Dir. of Survey
Upstream
Length Surveyed
369.4 ft.
Total Length
369.4 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
219
O&M Index
2
O&M Quick
2N00
O&M Rating
146
Overall Index
3
Overall Quick
Overall Rating
365
Pipe schematic from manhole 18 1192 to 18 1193
MH: 18 1192MH: 18 1193upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 11931.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish365.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start367.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start369.4 ft. MWL - Water Level, 5 %of cross sectional area369.4 ft. MWL - Water Level, 15 %of cross sectional area369.4 ft. AMH - Downstream Manhole, Survey Begins - 18 1192

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
0MWL
4CM
2DAGS
367.8CM
0AMH18 1192
369.4AMH18 1193
367.8DAGS

Properties (7)

additional_info
SC398761
custom_field_two
2
customer
LACSD
datetime
2020-01-16T22:47:51-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
31671