Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 2, 2016, 10:13 AM
  • 05 0818_05 0817 _12022016_021417.mp4

Date
12/02/2016
W/O
602600
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00419
PipeID
P06048
Time
2:13 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4026
Sewer Name
05 ARLINGTON AVENUE EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
11
Purpose
Routine Assessment
Project
WO_602600_TV05009_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 0818
Downstream MH
05 0817
Dir. of Survey
Downstream
Length Surveyed
245.6 ft.
Total Length
245.6 ft.
Structural Index
4
Structural Quick
5232
Structural Rating
16
O&M Index
2
O&M Quick
2I00
O&M Rating
96
Overall Index
2
Overall Quick
Overall Rating
112
Pipe schematic from manhole 05 0818 to 05 0817
MH: 05 0818MH: 05 0817downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 08180 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start22 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"24.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"70 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"72.6 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"124 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"126.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"174.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES176.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"214.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES219.7 ft. B - Broken, from 07 to 02 o'clock, within 8 inches of joint: YES, Start - POSSIBLE REPAIR VISIBLE223 ft. B - Broken, from 07 to 02 o'clock, within 8 inches of joint: YES, Finish224 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"226.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"243.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish245.6 ft. AMH - Downstream Manhole, Survey Ends - 05 0817245.6 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK245.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    175.6 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    214.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Broken, from 07 to 02 o'clock, within 8 inches of joint: YES, Start - POSSIBLE REPAIR VISIBLE

    219.7 ft. - Broken, from 07 to 02 o'clock, within 8 inches of joint: YES, Start - POSSIBLE REPAIR VISIBLE

Observations (23)

DistanceCodeObservation
124TFC
0MWL
214.7CM
245.6AMH05 0817
2DAGS
0MWM
245.6MGOACTIVE CONNECTION AT MH 9 O'CLOCK
224TFC
243.2DAGS
0AMH05 0818
174.2TFC
223B
24.6TFC
126.3TFC
22TFC
245.6MGOCOCKROACHES IN MANHOLE
219.7BPOSSIBLE REPAIR VISIBLE
72.6TFC
226.8TFC
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
176.8TFC
70TFC
175.6CM

Properties (6)

additional_info
SC306418
custom_field_two
3
customer
LACSD
datetime
2016-12-02T02:13:24-08:00
documentation
PRO PIPE
is_lateral_inspection
false