Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 29, 2016, 07:05 AM
  • 05 0836_05 0835 _11282016_230556.mp4

Date
11/28/2016
W/O
602600
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00419
PipeID
P06066
Time
11:05 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4023
Sewer Name
05 ARLINGTON AVENUE EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
Page No.
11
Purpose
Routine Assessment
Project
WO_602600_TV05009_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0836
Downstream MH
05 0835
Dir. of Survey
Downstream
Length Surveyed
245.7 ft.
Total Length
245.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2I00
O&M Rating
96
Overall Index
2
Overall Quick
Overall Rating
99
Pipe schematic from manhole 05 0836 to 05 0835
MH: 05 0836MH: 05 0835downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 08362 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start60.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"120.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"184.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"241.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES243.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish243.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE245.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK245.7 ft. AMH - Downstream Manhole, Survey Ends - 05 0835

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    241.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    243.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (12)

DistanceCodeObservation
0MWL
60.2TFC
245.7MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWM
243.6DAGS
241.3CM
243.6MGOCOCKROACHES IN MANHOLE
2DAGS
0AMH05 0836
120.8TFC
245.7AMH05 0835
184.8TFC

Properties (6)

additional_info
SC306415
custom_field_two
4
customer
LACSD
datetime
2016-11-28T23:05:38-08:00
documentation
PRO PIPE
is_lateral_inspection
false