Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 29, 2016, 10:20 AM
  • 05 0174_05 0173 _29112016_022038.mp4

Date
11/29/2016
W/O
602594
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05466
Time
2:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3835
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_602594_TV05228_NOV2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0173
Downstream MH
05 0174
Dir. of Survey
Upstream
Length Surveyed
329 ft.
Total Length
329 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 05 0173 to 05 0174
MH: 05 0173MH: 05 0174upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 017445.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"79 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"176.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"229.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"245 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"303.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"329 ft. AMH - Downstream Manhole, Survey Begins - 05 0173329 ft. MWM - Water Mark, 25 %of cross sectional area329 ft. MWL - Water Level, 15 %of cross sectional area

Observations (11)

DistanceCodeObservation
222.6TF
84TFA
25.5TF
329AMH05 0174
152.5TF
283.3TF
250TF
0AMH05 0173
0MWM
0MWL
99.1TF

Properties (7)

additional_info
SC304585
custom_field_two
4
customer
LACSD
datetime
2016-11-29T02:20:07-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP