Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2016, 12:07 PM
  • B 0571_B 0570 _11162016_042539.mp4

Date
11/16/2016
W/O
602270
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00101
PipeID
P09120
Time
4:07 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3880
Sewer Name
B JOINT OUTFALL B - UNIT 7
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
26
Purpose
Routine Assessment
Project
WO_602270_TV15120_NOV2016
Sewer Type
Gravity
Material
CIP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
B 0570
Downstream MH
B 0571
Dir. of Survey
Upstream
Length Surveyed
377.4 ft.
Total Length
377.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole B 0570 to B 0571
MH: B 0570MH: B 0571upstream0 ft. MGO - General Observation - LATERAL AT MH 3 O CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - B 05711.7 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish1.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish375.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start375.3 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start377.4 ft. MWL - Water Level, 5 %of cross sectional area377.4 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - AT MH377.4 ft. AMH - Downstream Manhole, Survey Begins - B 0570377.4 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWL
2.1DAGS
0VCAT MH
375.7SCP
2.1SCP
375.7DAGS
377.4MGOLATERAL AT MH 3 O CLOCK ACTIVE
0AMHB 0570
0MWM
377.4AMHB 0571

Properties (6)

additional_info
SC305212
custom_field_two
3
customer
LACSD
datetime
2016-11-16T04:07:35-08:00
documentation
PRO PIPE
is_lateral_inspection
false