Wastewater/Activity/PacpInspection/1.0Nov 22, 2016, 07:42 AM
  • B 0561_B 0835 _11212016_234935.mp4

Date
11/21/2016
W/O
602270
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00101
PipeID
P09109
Time
11:42 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3885
Sewer Name
B JOINT OUTFALL B - UNIT 7
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
WO_602270_TV15120_NOV2016
Sewer Type
Gravity
Material
CIP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
B 0561
Downstream MH
B 0835
Dir. of Survey
Downstream
Length Surveyed
36.1 ft.
Total Length
36.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
2112
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole B 0561 to B 0835
MH: B 0561MH: B 0835downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05610 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - AT MH2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start5.2 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start33.2 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish33.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish36.1 ft. MGO - General Observation - LATERAL AT MH 9 O CLOCK ACTIVE36.1 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - AT MH36.1 ft. AMH - Downstream Manhole, Survey Ends - B 0835

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
33.2SCP
2.2DAGS
36.1MGOLATERAL AT MH 9 O CLOCK ACTIVE
36.1VCAT MH
36.1AMHB 0835
0MWM
0MWL
0AMH0561
5.2SCP
0VCAT MH
33.2DAGS

Properties (6)

additional_info
SC305218
custom_field_two
4
customer
LACSD
datetime
2016-11-21T23:42:42-08:00
documentation
PRO PIPE
is_lateral_inspection