- Date
- 12/14/2016
- W/O
- 602270
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00101
- PipeID
- P09103
- Time
- 11:01 PM
- Certificate
- U507033386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3941
- Sewer Name
- B JOINT OUTFALL B - UNIT 7
- City
- MONTERAY PARK, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 27
- Purpose
- Routine Assessment
- Project
- WO_602270_TV15120_NOV2016
- Sewer Type
- Gravity
- Material
- CIP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- B 0556
- Downstream MH
- B 0555
- Dir. of Survey
- Downstream
- Length Surveyed
- 293 ft.
- Total Length
- 293 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 174
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 176
Pipe schematic from manhole B 0556 to B 0555 Observation photos (2)

2 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

284 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES