Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2018, 07:43 AM
  • 22 0286_22 0285_08012018_234348.mp4

Date
01/08/2018
W/O
679260
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16572
Time
11:43 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5407
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_679260_TV22014_JAN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0285
Downstream MH
22 0286
Dir. of Survey
Upstream
Length Surveyed
313.1 ft.
Total Length
313.1 ft.
Structural Index
3
Structural Quick
3K2K
Structural Rating
310
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
310
Pipe schematic from manhole 22 0285 to 22 0286
MH: 22 0285MH: 22 0286upstream0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 22 028620.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"69.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"118.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"138.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"178.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"272.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"311 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start311 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start313.1 ft. AMH - Downstream Manhole, Survey Begins - 22 0285313.1 ft. MWL - Water Level, 10 %of cross sectional area313.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK313.1 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (2)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
162.6TF
0AMH22 0285
0MWL
134.4TF
292.3TF
243.7TF
313.1SSS
174.7TF
40.8TF
0MGOCONNECTION AT MH 9 O'CLOCK
0MWM
2.1SSS
313.1SAP
313.1AMH22 0286
2.1SAP
194.9TF
259.8TF

Properties (6)

additional_info
SC346781
custom_field_two
2
customer
LACSD
datetime
2018-01-08T23:43:20-08:00
documentation
PROPIPE
is_lateral_inspection
false