Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2017, 08:30 AM
  • 15 0600_B 0629_532017_014049.mp4

Date
05/03/2017
W/O
0624373
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00107
PipeID
P09295
Time
1:30 AM
Certificate
U-1-14-06O22543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0514
Sewer Name
B JOINT OUTFALL B - UNIT 8D
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
20170503MDM_JOINT_OUTFALL_B_UNIT_8D
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
15 0600
Downstream MH
B 0629
Dir. of Survey
Downstream
Length Surveyed
420.7 ft.
Total Length
420.7 ft.
Structural Index
2
Structural Quick
2500
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 15 0600 to B 0629
MH: 15 0600MH: B 0629downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:30AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN , FLAKING CONCRETE22.2 ft. MGO - General Observation - COATING ON PIPE 60%28.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN ,FLAKING CONCRETE28.2 ft. MGO - General Observation - UNKNOWN COATING 50% START33.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE174.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN.FLAKING CONCRETE374.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - SWOLLEN,FLAKING CONCRETE420.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SWOLLEN ,FLAKING CONCRETE420.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. STUB420.3 ft. MGO - General Observation - UNKNOWN COATING 50% FINISH420.7 ft. AMH - Downstream Manhole, Survey Ends - 2:05AM

Observation photos (7)

  • Water Mark, 50 %of cross sectional area

    0 ft. - Water Mark, 50 %of cross sectional area

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN , FLAKING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN , FLAKING CONCRETE

  • General Observation - COATING ON PIPE 60%

    22.2 ft. - General Observation - COATING ON PIPE 60%

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN ,FLAKING CONCRETE

    28.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN ,FLAKING CONCRETE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE

    33.7 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN.FLAKING CONCRETE

    174.7 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN.FLAKING CONCRETE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - SWOLLEN,FLAKING CONCRETE

    374.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - SWOLLEN,FLAKING CONCRETE

Observations (16)

DistanceCodeObservation
420.7AMH2:05AM
0MWM
420.3SSSSWOLLEN ,FLAKING CONCRETE
420.3MGOConn. @ Mh, 3 O' Clock. STUB
0AMH1:30AM
0MGOConn. @ Mh, 9 O' Clock. Active
28.2SSSSWOLLEN ,FLAKING CONCRETE
22.2MGOCOATING ON PIPE 60%
28.2MGOUNKNOWN COATING 50% START
2SSSSWOLLEN , FLAKING CONCRETE
174.7SSSSWOLLEN.FLAKING CONCRETE
0MWL
33.7SSSFLAKING CONCRETE
0MGOConn. @ Mh, 3 O' Clock. Active
420.3MGOUNKNOWN COATING 50% FINISH
374.4SSSSWOLLEN,FLAKING CONCRETE

Properties (6)

custom_field_three
SPALLING CONCRETE
custom_field_two
4
customer
LACSD
datetime
2017-05-03T01:30:00-07:00
documentation
MARTIN,REVELES,OLIVER 111
is_lateral_inspection
false