Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2017, 07:37 AM
  • F 0333_F 0077 _09132017_003819.mp4

Date
09/13/2017
W/O
651806
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00037
PipeID
P10179
Time
12:37 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4969
Sewer Name
F JOINT OUTFALL F - UNIT 3B
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
WO_651806_TV02231_AUG2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Width
63 in.
Upstream MH
F 0333
Downstream MH
F 0077
Dir. of Survey
Downstream
Length Surveyed
120 ft.
Total Length
120 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole F 0333 to F 0077
MH: F 0333MH: F 0077downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - F 03334.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start4.4 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start120 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish120 ft. AMH - Downstream Manhole, Survey Ends - F 0077120 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
120SSS
120AMHF 0077
0MWL
0MWM
4.4SSS
120SAV
4.4SAV
0AMHF 0333

Properties (6)

additional_info
SC345961
custom_field_two
3
customer
LACSD
datetime
2017-09-13T00:37:40-07:00
documentation
PROPIPE
is_lateral_inspection
false