Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 27, 2020, 09:35 AM
  • J 0389_J 0074_1272020_020350.mp4

Date
01/27/2020
W/O
0808084
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00063
PipeID
P11654
Time
1:35 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1340
Sewer Name
J JOINT OUTFALL J - UNIT 2D
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
31
Purpose
Capital Improvement Program Assesment
Project
20200127MDM_JOINT_OUTFALL_J_UNIT_2D
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
J 0389
Downstream MH
J 0074
Dir. of Survey
Downstream
Length Surveyed
865.9 ft.
Total Length
865.9 ft.
Structural Index
3
Structural Quick
3625
Structural Rating
28
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
28
Pipe schematic from manhole J 0389 to J 0074
MH: J 0389MH: J 0074downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. MGO - General Observation - 99% MAG COAT START 8:00 TO 4:0047 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT64.8 ft. SAV - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC70.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, START - SEVERE AGG SPORATIC UNDER MAG COAT208.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT211.5 ft. MGO - General Observation - 95% MAG COAT START253.6 ft. SAV - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG297 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 8" - Active312.3 ft. SAV - Surface Aggregate Visible, from 12 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG323 ft. MGO - General Observation - 90% MAG COAT COAT START547.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE624.5 ft. MGO - General Observation - 90% MAG COAT START734.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG865.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES FINISH - BLISTERING PEELING CONCRETE865.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG865.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES FINISH - SEVERE AGG865.9 ft. AMH - Downstream Manhole, Survey Ends - 2:55AM

Observation photos (11)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • General Observation - 99% MAG COAT START 8:00 TO 4:00

    2 ft. - General Observation - 99% MAG COAT START 8:00 TO 4:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

    47 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

  • Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    64.8 ft. - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, START - SEVERE AGG SPORATIC UNDER MAG COAT

    70.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, START - SEVERE AGG SPORATIC UNDER MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

    208.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

  • Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

    253.6 ft. - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Visible, from 12 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    312.3 ft. - Surface Aggregate Visible, from 12 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

    547.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

  • General Observation - 90% MAG COAT START

    624.5 ft. - General Observation - 90% MAG COAT START

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    734.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

Observations (21)

DistanceCodeObservation
0MWL
734.4SAVSEVERE AGG
323MGO90% MAG COAT COAT START
865.4SSSBLISTERING PEELING CONCRETE
865.4SAVSEVERE AGG
211.5MGO95% MAG COAT START
0MWM
253.6SAVSEVERE AGG
0AMH1:55AM
624.5MGO90% MAG COAT START
865.9AMH2:55AM
865.4SAVSEVERE AGG
208.3SSSBLISTERING CONCRETE UNDER MAG COAT
2SSSBLISTERING PEELING CONCRETE
297TFActive
70.3SAVSEVERE AGG SPORATIC UNDER MAG COAT
47SSSBLISTERING CONCRETE UNDER MAG COAT
2MGO99% MAG COAT START 8:00 TO 4:00
64.8SAVSEVERE AGG SPORATIC
547.3SSSBLISTERING CONCRETE
312.3SAVSEVERE AGG

Properties (6)

custom_field_three
SEVERE AGG VISIBLE-90% MAG COAT
custom_field_two
3
customer
LACSD
datetime
2020-01-27T01:35:12-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false