Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2019, 06:05 AM
  • D 0211_D 0123 _12262019_224246.mp4

Date
12/26/2019
W/O
803087
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00156
PipeID
P10033
Time
10:05 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7221
Sewer Name
D JOINT OUTFALL D - UNIT 6
City
MANHATTAN BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_803087_TV05172_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
D 0211
Downstream MH
D 0123
Dir. of Survey
Downstream
Length Surveyed
315.8 ft.
Total Length
315.8 ft.
Structural Index
4
Structural Quick
5233
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
19
Pipe schematic from manhole D 0211 to D 0123
MH: D 0211MH: D 0123downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - D 02112.1 ft. MGO - General Observation - MAG COAT105.8 ft. SAV - Surface Aggregate Visible, at 12 o'clock, within 8 inches of joint: YES202.6 ft. SAP - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES203 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES247.7 ft. SAP - Surface Aggregate Projecting, from 01 to 02 o'clock, within 8 inches of joint: YES261.8 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start315.7 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Finish315.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK315.8 ft. AMH - Downstream Manhole, Survey Ends - D 0123

Observation photos (5)

  • Surface Aggregate Visible, at 12 o'clock, within 8 inches of joint: YES

    105.8 ft. - Surface Aggregate Visible, at 12 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES

    202.6 ft. - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    203 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 01 to 02 o'clock, within 8 inches of joint: YES

    247.7 ft. - Surface Aggregate Projecting, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start

    261.8 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start

Observations (12)

DistanceCodeObservation
2.1MGOMAG COAT
315.8MGOCONNECTION AT MH 9 O'CLOCK
0MWL
261.8SRC
0MWM
247.7SAP
203SRV
105.8SAV
315.7SRC
0AMHD 0211
315.8AMHD 0123
202.6SAP

Properties (6)

additional_info
SC398513
custom_field_two
3
customer
LACSD
datetime
2019-12-26T22:05:25-08:00
documentation
PROPIPE
is_lateral_inspection
false