Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2019, 08:53 AM
  • D 0098_D 0097 _12302019_011503.mp4

Date
12/30/2019
W/O
803087
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00156
PipeID
P10004
Time
12:53 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7222
Sewer Name
D JOINT OUTFALL D - UNIT 6
City
LAWNDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_803087_TV05172_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
D 0098
Downstream MH
D 0097
Dir. of Survey
Downstream
Length Surveyed
343.8 ft.
Total Length
343.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole D 0098 to D 0097
MH: D 0098MH: D 0097downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - D 00982.1 ft. MGO - General Observation - MAG COAT18.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start110.2 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"195.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"340.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish343.8 ft. AMH - Downstream Manhole, Survey Ends - D 0097343.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK343.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    18.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    110.2 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

Observations (13)

DistanceCodeObservation
340.2SAP
0MGOCONNECTION AT MH 3 O'CLOCK
343.8AMHD 0097
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
2.1MGOMAG COAT
343.8MGOCONNECTION AT MH 9 O'CLOCK
110.2TBI
18.5SAP
0MWL
195.2TF
343.8MGOCONNECTION AT MH 3 O'CLOCK
0AMHD 0098

Properties (6)

additional_info
SC398514
custom_field_two
3
customer
LACSD
datetime
2019-12-30T00:53:52-08:00
documentation
PROPIPE
is_lateral_inspection
false