Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 10, 2020, 10:27 AM
  • 18 0215_18 0214 _01102020_024016.mp4

Date
01/10/2020
W/O
803057
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00695
PipeID
P14041
Time
2:27 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7269
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_803057_TV18100_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0215
Downstream MH
18 0214
Dir. of Survey
Downstream
Length Surveyed
27.8 ft.
Total Length
27.8 ft.
Structural Index
4
Structural Quick
5A35
Structural Rating
75
O&M Index
2
O&M Quick
2500
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
85
Pipe schematic from manhole 18 0215 to 18 0214
MH: 18 0215MH: 18 0214downstream0 ft. MGO - General Observation - APPARENTLY ACTIVE CONNECTIONS @ 9 & 3 O'CLOCK - U/S MH0 ft. AMH - Upstream Manhole, Survey Begins - 18 02150 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start25.7 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish25.7 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish25.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish25.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish25.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish27.8 ft. AMH - Downstream Manhole, Survey Ends - 18 021427.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE27.8 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    27.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
25.7SRV
0MGOAPPARENTLY ACTIVE CONNECTIONS @ 9 & 3 O'CLOCK - U/S MH
2DAGS
25.7SRC
0AMH18 0215
25.7DAGS
25.7SAP
0MWM
2SRC
2SAP
27.8AMH18 0214
27.8MGOCOCKROACHES IN MANHOLE
0MWL
2SSS
25.7SSS
2SRV
27.8MGOACTIVE CONNECTION AT MH 3 O'CLOCK

Properties (6)

additional_info
SC398754
custom_field_two
1
customer
LACSD
datetime
2020-01-10T02:27:59-08:00
documentation
PRO PIPE
is_lateral_inspection
false