Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2020, 11:49 AM
  • B 1115_B 1523 _01132020_035725.mp4

Date
01/13/2020
W/O
802972
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01124
PipeID
P25638
Time
3:49 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7272
Sewer Name
B JOINT OUTFALL B - UNIT 6G
City
ALHAMBRA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_802972_TV16038_DEC2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
B 1115
Downstream MH
B 1523
Dir. of Survey
Downstream
Length Surveyed
5.8 ft.
Total Length
5.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole B 1115 to B 1523
MH: B 1115MH: B 1523downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 11150 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish5.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK5.8 ft. AMH - Downstream Manhole, Survey Ends - B 1523

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
5DAGS
0AMHB 1115
2DAGS
0MWL
0MGOCONNECTION AT MH 9 O'CLOCK
5.8MGOCONNECTION AT MH 3 O'CLOCK
5.8AMHB 1523
0MWM

Properties (7)

additional_info
SC398757
custom_field_two
3
customer
LACSD
datetime
2020-01-13T03:49:11-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
38973