Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 17, 2020, 01:03 PM
  • 18 0473_18 0472_1172020_051817.mp4

Date
01/17/2020
W/O
0808176
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00691
PipeID
P14327
Time
5:03 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1332
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Capital Improvement Program Assesment
Project
20200117_NORTH_PLANT_OUTFALL_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
18 0472
Downstream MH
18 0473
Dir. of Survey
Upstream
Length Surveyed
87.2 ft.
Total Length
87.2 ft.
Structural Index
5
Structural Quick
5841
Structural Rating
46
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
53
Pipe schematic from manhole 18 0472 to 18 0473
MH: 18 0472MH: 18 0473upstream0 ft. AMH - Upstream Manhole, Survey Ends - 5:40AM3.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE3.3 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LOING CIRCUM REBAR3.3 ft. RMJ - Roots Medium Joint, from 09 to 03 o'clock, 5 %, within 8 inches of joint: YESR3.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG3.3 ft. SRC - Surface Reinforcement Corroded, from 09 to 11 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR10.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR21.6 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR39.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR52.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR59.5 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REAR59.5 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR59.5 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR69 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open77.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE77.8 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR79.2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM LONG REBARREBAR81.2 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR84.2 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM LONG REBAR85.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG87.2 ft. MWM - Water Mark, 50 %of cross sectional area87.2 ft. AMH - Downstream Manhole, Survey Begins - 5:15AM87.2 ft. MWL - Water Level, 40 %of cross sectional area

Observation photos (10)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM LONG REBAR

    3 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM LONG REBAR

  • Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    6 ft. - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM LONG REBARREBAR

    8 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM LONG REBARREBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    9.4 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    9.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Corroded, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    35.1 ft. - Surface Reinforcement Corroded, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    48 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    65.6 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    77 ft. - Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

Observations (23)

DistanceCodeObservation
9.9SSSBLISTERING PEELING CONCRETE
0MWM
87.2AMH5:40AM
0AMH5:15AM
8SRVCIRCUM LONG REBARREBAR
0MWL
27.7SRVLONG CIRCUM REAR
27.7SRCLONG CIRCUM REBAR
83.9SSSBLISTERING PEELING CONCRETE
18.2TFOpen
65.6SRCLONG CIRCUM REBAR
27.7SRVLONG CIRCUM REBAR
48SRCLONG CIRCUM REBAR
3SRVCIRCUM LONG REBAR
6SRVLONG CIRCUM REBAR
83.9SRCLOING CIRCUM REBAR
77SRCCIRCUM REBAR
35.1SRCCIRCUM REBAR
83.9RMJ
83.9SAMSEVERE AGG
83.9SRCLONG CIRCUM REBAR
2SAMSEVERE AGG
9.4SRCLONG CIRCUM REBAR

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED
custom_field_two
2
customer
LACSD
datetime
2020-01-17T05:03:14-08:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false