Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 15, 2020, 11:31 AM
  • B 0473A_B 0473_1152020_034435.mp4

Date
01/15/2020
W/O
0808599
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00094
PipeID
P08998
Time
3:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1328R
Sewer Name
B JOINT OUTFALL B - UNIT 5D
City
ALTADENA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
06
Purpose
Maintenance Related
Project
20201015MDM_JOINT_OUTFALL_B_UNIT_5D
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
B 0473
Downstream MH
B 0473A
Dir. of Survey
Upstream
Length Surveyed
79.7 ft.
Total Length
79.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole B 0473 to B 0473A
MH: B 0473MH: B 0473Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 4:00AM50.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open50.1 ft. RMC - Roots Medium Connection, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES71.7 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YESR - 1%79.7 ft. MWM - Water Mark, 30 %of cross sectional area79.7 ft. AMH - Downstream Manhole, Survey Begins - 3:50AM79.7 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Roots Medium Connection, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES

    29.6 ft. - Roots Medium Connection, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
29.6TFOpen
0MWM
0AMH3:50AM
79.7AMH4:00AM
29.6RMC
0MWL
8RFJ1%

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-01-15T03:31:13-08:00
documentation
MARTIN,OLIVER 111,IGNACIO
is_lateral_inspection
false