B 0379_B 0378_1142020_022709.mp4
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING FLAKING PEELING CONCRETE
8.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING CONCRETE
14.5 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
40.9 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
112.3 ft. - Surface Aggregate Projecting, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
184.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
221.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 2:25AM |
| 40.9 | SAV | SEVERE AGG |
| 0 | MWM | — |
| 8.9 | SSS | PEELING CONCRETE |
| 112.3 | SAP | SEVERE AGG |
| 221.9 | SAP | SEVERE AGG |
| 331.8 | AMH | 3:00AM |
| 2 | SSS | BLISTERING FLAKING PEELING CONCRETE |
| 331.4 | SAV | SEVERE AGG |
| 14.5 | SAV | SEVERE AGG SPORATIC |
| 184.9 | SAP | SEVERE AGG SPORATIC |
| 331.4 | SAP | SEVERE AGG |
| 0 | MWL | — |
| 331.4 | SSS | BLISTERING FLAKING PEELING CONCRETE |