Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 31, 2019, 06:47 AM
  • 29 0085_29 0084 _12302019_230307.mp4

Date
12/30/2019
W/O
803101
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00265
PipeID
P23865
Time
10:47 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7225
Sewer Name
29 33RD STREET TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_803101_TV29110_DEC2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0085
Downstream MH
29 0084
Dir. of Survey
Downstream
Length Surveyed
331 ft.
Total Length
331 ft.
Structural Index
4
Structural Quick
5141
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
12
Pipe schematic from manhole 29 0085 to 29 0084
MH: 29 0085MH: 29 0084downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 00850 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK - 50 % DEBRIS OF CROSS-SECTION0 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. MWM - Water Mark, 25 %of cross sectional area4.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start18.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN - NO FLOW SEEN @ THIS TIME21.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN - NO FLOW SEEN @ THIS TIME - FRACTURE IN TAP59.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish59.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start74.7 ft. B - Broken, from 07 to 05 o'clock, within 8 inches of joint: YES311.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN - NO FLOW SEEN @ THIS TIME314.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN - NO FLOW SEEN @ THIS TIME327.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish331 ft. AMH - Downstream Manhole, Survey Ends - 29 0084331 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK331 ft. MGO - General Observation - ACTIVE DROP CONNECTION AT MH 3 O'CLOCK

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    59.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 07 to 05 o'clock, within 8 inches of joint: YES

    74.7 ft. - Broken, from 07 to 05 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
314.1TFOPEN - NO FLOW SEEN @ THIS TIME
59.1CM
21.8TFOPEN - NO FLOW SEEN @ THIS TIME - FRACTURE IN TAP
18.1TFOPEN - NO FLOW SEEN @ THIS TIME
0AMH29 0085
327.3FM
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
331AMH29 0084
331MGOACTIVE CONNECTION AT MH 9 O'CLOCK
4.9CM
0.1MWM
311.7TFOPEN - NO FLOW SEEN @ THIS TIME
59.1FM
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK - 50 % DEBRIS OF CROSS-SECTION
0MWL
74.7B
331MGOACTIVE DROP CONNECTION AT MH 3 O'CLOCK

Properties (6)

additional_info
SC398517
custom_field_two
1
customer
LACSD
datetime
2019-12-30T22:47:08-08:00
documentation
PROPIPE
is_lateral_inspection
false