- Date
- 12/18/2019
- W/O
- 803104
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00091
- PipeID
- P08913
- Time
- 3:45 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7190
- Sewer Name
- B JOINT OUTFALL B - UNIT 5A
- City
- ARCADIA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- RFIR_WO_803104_TV15134_DEC2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- B 0401
- Downstream MH
- B 0400
- Dir. of Survey
- Downstream
- Length Surveyed
- 304.4 ft.
- Total Length
- 304.4 ft.
- Structural Index
- 3
- Structural Quick
- 3K2K
- Structural Rating
- 295
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 298
Pipe schematic from manhole B 0401 to B 0400 Observation photos (3)

6.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

6.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

54.2 ft. - Roots Medium Lateral, from 08 to 10 o'clock, 10 %, within 8 inches of joint: NO