Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 3, 2019, 08:04 AM
  • 05 0363_05 0362 _12032019_000925.mp4

Date
12/03/2019
W/O
798212
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P05578
Time
12:04 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6348
Sewer Name
05 DISTRICT #5 MAIN RELIEF TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_798212_TV05012_NOV2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
05 0363
Downstream MH
05 0362
Dir. of Survey
Downstream
Length Surveyed
13.5 ft.
Total Length
13.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 0363 to 05 0362
MH: 05 0363MH: 05 0362downstream0 ft. MWL - Water Level, 55 %of cross sectional area0 ft. MWM - Water Mark, 65 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 03632.1 ft. MGO - General Observation - MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish13.5 ft. MGO - General Observation - CONNECTION @ D/S MH 9 O'CLOCK - (UNKNOWN FLOW STATUS @ THIS TIME)13.5 ft. AMH - Downstream Manhole, Survey Ends - 05 0362

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
13.5SAV
13.5MGOCONNECTION @ D/S MH 9 O'CLOCK - (UNKNOWN FLOW STATUS @ THIS TIME)
2.1MGOMAG COAT
13.5AMH05 0362
2.1SAV
0MWM
0AMH05 0363

Properties (6)

additional_info
SC365791
custom_field_two
3
customer
LACSD
datetime
2019-12-03T00:04:04-08:00
documentation
PROPIPE
is_lateral_inspection
false