Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 26, 2019, 09:59 AM
Date
11/26/2019
W/O
798212
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P05566
Time
1:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6343
Sewer Name
05 DISTRICT #5 MAIN RELIEF TRUNK
City
HAWTHRONE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
WO_798212_TV05012_NOV2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
05 0351A
Downstream MH
05 0351
Dir. of Survey
Downstream
Length Surveyed
242 ft.
Total Length
242 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
144
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
144
Pipe schematic from manhole 05 0351A to 05 0351
MH: 05 0351AMH: 05 0351downstream0 ft. AMH - Upstream Manhole, Survey Begins - U/S MH DOES NOT EXIST3 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start242 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish242 ft. AMH - Downstream Manhole, Survey Ends - MH 351

Observations (4)

DistanceCodeObservation
242SAV
0AMHU/S MH DOES NOT EXIST
242AMHMH 351
3SAV

Properties (6)

additional_info
U/S MH DOES NOT EXIST, MPEG IS THE SECOND HALF OF MH 352 TO 351A
custom_field_two
3
customer
LACSD
datetime
2019-11-26T01:59:00-08:00
documentation
PROPIPE
is_lateral_inspection
false