Wastewater/Activity/PacpInspection/1.0Dec 4, 2019, 09:21 AM
  • 05 0383C_05 0383B _12042019_012634.mp4

Date
12/04/2019
W/O
798212
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P25938
Time
1:21 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6350
Sewer Name
05 DISTRICT #5 MAIN RELIEF TRUNK
City
LENNOX
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_798212_TV05012_NOV2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
05 0383C
Downstream MH
05 0383B
Dir. of Survey
Downstream
Length Surveyed
159.3 ft.
Total Length
159.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 0383C to 05 0383B
MH: 05 0383CMH: 05 0383Bdownstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 0383C0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 60 %of cross sectional area2.4 ft. MGO - General Observation - MAG COAT52.7 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO159.3 ft. AMH - Downstream Manhole, Survey Ends - 05 0383B

Observation photos (1)

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    52.7 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

Observations (6)

DistanceCodeObservation
0AMH05 0383C
2.4MGOMAG COAT
159.3AMH05 0383B
0MWL
0MWM
52.7SAV

Properties (7)

additional_info
SC365793
custom_field_two
3
customer
LACSD
datetime
2019-12-04T01:21:08-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
39052