Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2019, 09:52 AM
  • 02 0720_02 0719A_12182019_020450.mp4

Date
12/18/2019
W/O
803134
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00294
PipeID
P03274
Time
1:52 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7216
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
29
Purpose
Routine Assessment
Project
RFIR_WO_803134_TV02351_DEC2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0720
Downstream MH
02 0719A
Dir. of Survey
Downstream
Length Surveyed
317.7 ft.
Total Length
317.7 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 02 0720 to 02 0719A
MH: 02 0720MH: 02 0719Adownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 07203.6 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start7.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"9.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"95.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"97.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"218.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"221 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"317.7 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish317.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0719A

Observation photos (1)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
218.1TF
221TF
0MWM
95.1TF
97.4TFC
3.6FM
317.7FM
7.2TFC
9.8TFC
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
0AMH02 0720
317.7AMH02 0719A

Properties (6)

additional_info
SC398508
custom_field_two
2
customer
LACSD
datetime
2019-12-18T01:52:05-08:00
documentation
PROPIPE
is_lateral_inspection
false