D 0125_D 0124_01042016_Manual.mp4
2 ft. - General Observation - MISSING TILES 100% START 8:00 TO 4:00
2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
2 ft. - General Observation - MAG COAT 50% START
2.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG REBAR
7.5 ft. - General Observation - MISSING TILES 30%
18.3 ft. - Surface Aggregate Projecting, from 12 to 04 o'clock, within 8 inches of joint: YES, Start
20 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES - CORODDED BEYOUND REBAR
25.5 ft. - General Observation - MAG COAT 70% START
25.5 ft. - Surface Reinforcement Corroded, from 12 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
34.5 ft. - Surface Aggregate Projecting, from 12 to 04 o'clock, within 8 inches of joint: YES, Finish - CIRCUM
73.4 ft. - General Observation - MISSING TILES 20%
107.5 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CORRODED BEYOUND REBAR
107.5 ft. - General Photograph
111.1 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CORRODED BEYOUND REBAR
128 ft. - General Observation - MISSING TILES 20%
144.8 ft. - General Observation - MISSING TILES 30%
181.2 ft. - General Observation - MISSING TILES 20%
206 ft. - General Observation - MISSING TILES 50%
232.4 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM
236.3 ft. - General Observation - MISSING TILES 20%
262.4 ft. - General Observation - MISSING TILES 20%
285.8 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO
302.2 ft. - General Observation - MISSING TILES 20%
320 ft. - General Observation - MISSING TILES 20%
359.8 ft. - General Observation - MISSING TILES 30%
378 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO
382.2 ft. - General Observation - MISSING TILES 20%
434.9 ft. - Surface Reinforcement Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM
447.4 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CORRODED BEYOUND REBAR
452.2 ft. - General Photograph
457 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - CORRODED BEYOUND REBAR
461.6 ft. - General Photograph
469.7 ft. - General Photograph
521.5 ft. - General Photograph
568.4 ft. - Surface Reinforcement Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM
575.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - REBAR MISSING-CORRODED BEYOUND REBAR
582.1 ft. - General Photograph
633 ft. - General Photograph
658.9 ft. - General Photograph
| Distance | Code | Observation |
|---|---|---|
| 633 | MGP | — |
| 232.4 | SAP | CIRCUM |
| 658.9 | MGP | — |
| 0 | MWM | — |
| 111.1 | SRC | CORRODED BEYOUND REBAR |
| 521.5 | MGP | — |
| 378 | SRC | — |
| 359.8 | MGO | MISSING TILES 30% |
| 0 | MGO | MH CONN OPEN STOPLOG IN PLACE 3:00 |
| 73.4 | MGO | MISSING TILES 20% |
| 457 | SRC | CORRODED BEYOUND REBAR |
| 447.4 | SRC | CORRODED BEYOUND REBAR |
| 673.5 | AMH | 3:25AM |
| 575.2 | SRC | REBAR MISSING-CORRODED BEYOUND REBAR |
| 34.5 | SAP | CIRCUM |
| 2 | SAM | SEVERE AGG |
| 107.5 | SRC | CORRODED BEYOUND REBAR |
| 128 | MGO | MISSING TILES 20% |
| 673.1 | SRC | — |
| 181.2 | MGO | MISSING TILES 20% |
| 2.2 | SRC | LONG REBAR |
| 673.1 | SRC | REBAR MISSING-CORRODED BEYOUND REBAR |
| 582.1 | MGP | — |
| 2 | MGO | MISSING TILES 100% START 8:00 TO 4:00 |
| 2 | SRC | CIRCUM REBAR |
| 25.5 | MGO | MAG COAT 70% START |
| 452.2 | MGP | — |
| 25.5 | SRC | CIRCUM REBAR |
| 206 | MGO | MISSING TILES 50% |
| 673.1 | SRC | — |
| 673.1 | MGO | MISSING TILES 100% FINISH |
| 434.9 | SRP | CIRCUM |
| 320 | MGO | MISSING TILES 20% |
| 7.5 | MGO | MISSING TILES 30% |
| 382.2 | MGO | MISSING TILES 20% |
| 461.6 | MGP | — |
| 0 | MWL | — |
| 673.1 | SAM | — |
| 568.4 | SRP | CIRCUM |
| 302.2 | MGO | MISSING TILES 20% |
| 18.3 | SAP | — |
| 0 | AMH | 2:25AM |
| 673.1 | MGO | MAG COAT 70% FINISH |
| 20 | SRC | CORODDED BEYOUND REBAR |
| 262.4 | MGO | MISSING TILES 20% |
| 673.1 | SRP | — |
| 144.8 | MGO | MISSING TILES 30% |
| 2 | MGO | MAG COAT 50% START |
| 285.8 | SRC | — |
| 107.5 | MGP | — |
| 236.3 | MGO | MISSING TILES 20% |
| 469.7 | MGP | — |