Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2019, 07:10 AM
  • 05 2484_05 2483 _12042019_232724.mp4

Date
12/04/2019
W/O
798297
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00462
PipeID
P20879
Time
11:10 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6351
Sewer Name
05 INGLEWOOD TRUNK #1 RELIEF
City
INGLEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_798297_TV05326_NOV2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 2484
Downstream MH
05 2483
Dir. of Survey
Downstream
Length Surveyed
489.2 ft.
Total Length
489.2 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 05 2484 to 05 2483
MH: 05 2484MH: 05 2483downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 24841.9 ft. MGO - General Observation - HEAVY STEAM35.9 ft. MWLS - Water Level, Sag in pipe, 25 %of cross sectional area59.3 ft. FC - Fracture Circumferential, from 10 to 04 o'clock, within 8 inches of joint: YES245.7 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start321 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish321 ft. RFJ - Roots Fine Joint, from 09 to 12 o'clock, within 8 inches of joint: YES488.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK489.2 ft. AMH - Downstream Manhole, Survey Ends - 05 2483

Observation photos (3)

  • Water Level, Sag in pipe, 25 %of cross sectional area

    35.9 ft. - Water Level, Sag in pipe, 25 %of cross sectional area

  • Fracture Circumferential, from 10 to 04 o'clock, within 8 inches of joint: YES

    59.3 ft. - Fracture Circumferential, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Settled Other,  15 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    245.7 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
35.9MWLS
321DSZ
0MGOCONNECTION AT MH 9 O'CLOCK
321RFJ
245.7DSZ
59.3FC
489.2AMH05 2483
1.9MGOHEAVY STEAM
0MWL
488.8MGOCONNECTION AT MH 3 O'CLOCK
0MWM
0AMH05 2484

Properties (7)

additional_info
SC365794
custom_field_two
3
customer
LACSD
datetime
2019-12-04T23:10:07-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
35144